Free Cooling and Economizers: Cutting Chiller Hours with Outside Air or Water
When the weather is cool enough, a data center can reject heat without running its chillers.
Key takeaways
- Free cooling uses cool outdoor air or water to remove heat, so mechanical cooling runs less.
- Air-side and water-side economizers suit different climates and designs.
- Savings depend on local weather, supply temperatures and how well the controls are tuned.
Chillers use a lot of electricity. If outdoor conditions are cool enough, a data center may be able to skip the chillers for part of the year and move heat out directly. This is called free cooling, although the fans and pumps still use power. The more accurate name is economizer operation.
Air-side economizers
An air-side economizer brings filtered outside air into the data hall, or uses it to cool the hall air through a heat exchanger. When outside air is cool and dry enough, it replaces mechanical cooling. Some designs mix outside air with warm return air to reach the target temperature. Others use evaporative assistance to extend the hours of use.
Air-side designs need attention to humidity, dust, smoke and chemical contaminants. Filtration and monitoring are important because sensitive equipment can be harmed by poor air quality.
Water-side economizers
A water-side economizer works with a chilled water plant. When the outdoor air is cold enough, the cooling towers or dry coolers can chill the water directly through a heat exchanger, and the chillers are bypassed or shut off. The data hall never sees outside air, which avoids many air quality concerns. Many large facilities prefer this approach for that reason.
Plants may run in three modes: full mechanical cooling, a partial mode where the economizer pre-cools the water and the chillers finish the job, and full economizer mode.
What decides how much it helps
- Climate: cooler and drier regions generally offer more economizer hours. Hot, humid regions offer fewer.
- Supply temperature: the warmer the water or air the equipment can accept, the more hours the economizer can carry the load. Modern server guidance allows warmer temperatures than older practice.
- Load profile: steady high loads produce a lot of heat, so the outside conditions need to be cooler to keep up.
- Controls: switching smoothly between modes is where many projects succeed or fail.
Tradeoffs
Economizers add equipment, piping, valves and control logic, which raises first cost and complexity. Water-side systems that use towers still consume water through evaporation. Air-side systems can reduce water use but may need more filtration. Freezing, condensation and mode changes need careful design.
It also helps to remember that outdoor conditions change by the hour and by season. A design should be judged on a full year of weather data, not on a few good days. Operators should also plan for the hottest and coldest conditions, since the system must still carry the full load when the economizer cannot help.
Questions to ask
- How many hours per year does the design expect to run in each mode, and what weather data supports that?
- What supply temperatures are assumed?
- Is the economizer air-side or water-side, and why?
- How does the system transition between modes without disturbing the data hall?
- How are air quality or freeze risks handled?
- Will mode changes be tested during commissioning?
Free cooling is not a guarantee of savings. It is a design opportunity that pays off when climate, temperatures and controls line up.
This article is general information for public education. It is not legal, tax, financial or engineering advice. Rules and conditions differ by location, so check with qualified local professionals. Spot an error? Write to info@datacenteroutreach.com and we will correct it.