Hot Aisle and Cold Aisle Containment Explained

Separating cool supply air from hot exhaust air is one of the simplest ways to cool servers more efficiently.

Key takeaways

  • Servers draw cool air in the front and push hot air out the back, so rows are arranged to keep the two streams apart.
  • Containment uses physical barriers to stop hot and cold air from mixing, which often lets cooling run more efficiently.
  • Cold aisle and hot aisle designs each have tradeoffs in comfort, cost and retrofit effort.

Air cooled data halls depend on a basic idea: give servers cool air and take the hot air away before it can mix back in. Containment is the set of physical barriers that makes this work.

The starting point: hot and cold aisles

Most servers pull air in at the front and exhaust it at the back. If every rack faces the same direction, one row blows hot air into the next row's intake. The fix is to face racks in alternating directions. Fronts face fronts across a cold aisle, and backs face backs across a hot aisle.

Why mixing is the problem

Without barriers, hot exhaust air curls over the top of racks and around the ends of rows. It warms the intake air of nearby servers. Cooling systems then have to supply colder air, or move more of it, to compensate. This wastes energy and can create hot spots. Air also leaks back through gaps, such as empty rack spaces.

Two ways to contain

Cold aisle containment. Doors at the ends of the cold aisle and a roof over it seal the supply air in. Servers draw from this enclosed space. The rest of the room becomes the warm side, and warm air returns to the cooling units.

Hot aisle containment. The hot aisle is enclosed instead, often with a ducted ceiling plenum that carries exhaust air directly back to the cooling equipment. The rest of the room is then close to the supply temperature.

  • With cold aisle containment, the general room feels warm, which can affect people working in it.
  • With hot aisle containment, the room is more comfortable, but the enclosed hot aisle can be quite hot for anyone inside it.
  • Retrofits in existing rooms may favor whichever approach fits the ceiling and cooling layout.

Some designs use chimney style cabinets that duct hot air from the rack straight up to a return, which is a related approach.

What containment can improve

Better separation typically allows higher supply air temperatures and lower fan effort, both of which can reduce cooling energy. It can also make temperatures across a room more even. Actual gains vary by design and by how well the barriers are sealed.

Details that make or break it

  • Blanking panels fill empty rack spaces so air cannot pass through.
  • Seals around cable openings, floor tiles and rack edges reduce leaks.
  • Airflow balance matters. Cooling units should supply roughly the volume the servers consume.
  • Fire safety must be considered. Containment materials, detection and suppression need to be coordinated with local codes.

A short checklist

  1. Are racks arranged in a consistent hot and cold aisle pattern?
  2. Is there a physical barrier between supply and return air?
  3. Are all unused rack spaces and openings blocked?
  4. Are temperatures measured at the server intake, not only at the cooling unit?
  5. Has the fire protection design been reviewed with the containment in place?